🎉 Up to 70% Off Selected ItemsShop Sale
HomeStore

Stabilizer Powder Packets for Sulfur Dioxide Mini Titrator - 100 Packets (Hanna# HI84500-62)

Product image 1

Stabilizer Powder Packets for Sulfur Dioxide Mini Titrator - 100 Packets (Hanna# HI84500-62)

The HI84500-62 are packets of stabilizer reagent required for determination of sulfur dioxide in wine using the HI84500 Sulfur Dioxide Mini Titrator for Wine Analysis. The HI84500 mini titrator uses two different titrant solutions that contain different concentrations of potassium iodate to measure a wide range of sulfur dioxide concentration in wine. Both low and high range measurements require the addition of HI84500-62 stabilizer powder to convert iodate into iodine, which in turn reacts with sulfur dioxide. The HI84500-62 powder is packaged into single use packets that are emptied into the sample prior to performing the titration.
  • Pre-measured packets
  • Clearly marked expiration date and lot number
The HI84500-62 stabilizer powder packets are necessary to convert the iodate titrant into iodine. The iodine then reacts with sulfur dioxide and the HI3148B ORP electrode is used to detect the endpoint for both the low (1.0 to 40.0 ppm of SO2) and high (30 to 400 ppm of SO2) ranges. The decision by Hanna to use the HI84500-62 stabilizer powder packets and iodate titrant in place of a iodine titrant is due to shelf stability. Iodate offers much greater shelf stability than iodine. By using stabilizer packets the titrant solutions remain stable for longer periods of time.The HI84500 can be used with all wines, including red, which are difficult to test using traditional methods due to the difficulty to observe a distinctive color change when the endpoint is reached.
 
The HI84500 determines the free and total sulfur dioxide concentration in wine using the Ripper method. Excess iodide is added to the wine sample and reacts with the iodate titrant to produce iodine:
 
IO3- + 5I- + 6H+ → 3I2 + 3H2O
 
The iodine produced reacts with sulfur dioxide in the wine according to the redox reaction below:
 
H2SO3 + I2 → H2SO4 + 2HI
 
Replacement reagents required to operate the HI84500 include:
  Low Range - 1.0 to 40.0 ppm of SO2 High Range - 30 to 400 ppm of SO2
Pump calibration standard HI84500-55 HI84500-55
Titrant solution HI84500-50 HI84500-51
Acid reagent HI84500-60 HI84500-60
Alkaline reagent (Total SO2) HI84500-61 HI84500-61
Stabilizer powder packets HI84500-62 HI84500-62
 
 
$16.80

Original: $48.00

-65%
Stabilizer Powder Packets for Sulfur Dioxide Mini Titrator - 100 Packets (Hanna# HI84500-62)

$48.00

$16.80

Product Information

Shipping & Returns

Description

The HI84500-62 are packets of stabilizer reagent required for determination of sulfur dioxide in wine using the HI84500 Sulfur Dioxide Mini Titrator for Wine Analysis. The HI84500 mini titrator uses two different titrant solutions that contain different concentrations of potassium iodate to measure a wide range of sulfur dioxide concentration in wine. Both low and high range measurements require the addition of HI84500-62 stabilizer powder to convert iodate into iodine, which in turn reacts with sulfur dioxide. The HI84500-62 powder is packaged into single use packets that are emptied into the sample prior to performing the titration.
  • Pre-measured packets
  • Clearly marked expiration date and lot number
The HI84500-62 stabilizer powder packets are necessary to convert the iodate titrant into iodine. The iodine then reacts with sulfur dioxide and the HI3148B ORP electrode is used to detect the endpoint for both the low (1.0 to 40.0 ppm of SO2) and high (30 to 400 ppm of SO2) ranges. The decision by Hanna to use the HI84500-62 stabilizer powder packets and iodate titrant in place of a iodine titrant is due to shelf stability. Iodate offers much greater shelf stability than iodine. By using stabilizer packets the titrant solutions remain stable for longer periods of time.The HI84500 can be used with all wines, including red, which are difficult to test using traditional methods due to the difficulty to observe a distinctive color change when the endpoint is reached.
 
The HI84500 determines the free and total sulfur dioxide concentration in wine using the Ripper method. Excess iodide is added to the wine sample and reacts with the iodate titrant to produce iodine:
 
IO3- + 5I- + 6H+ → 3I2 + 3H2O
 
The iodine produced reacts with sulfur dioxide in the wine according to the redox reaction below:
 
H2SO3 + I2 → H2SO4 + 2HI
 
Replacement reagents required to operate the HI84500 include:
  Low Range - 1.0 to 40.0 ppm of SO2 High Range - 30 to 400 ppm of SO2
Pump calibration standard HI84500-55 HI84500-55
Titrant solution HI84500-50 HI84500-51
Acid reagent HI84500-60 HI84500-60
Alkaline reagent (Total SO2) HI84500-61 HI84500-61
Stabilizer powder packets HI84500-62 HI84500-62
 
 

You may also like

NEW
Thumbnail 1

ProRestart Uvaferm 43 Encapsulated Wine Yeast - (83 g) & 1 mesh bag

$54.99

-65%NEW
Thumbnail 1

Plastic Hose Barb - 1/2 in. x 1/2 in. FPT

$5.49

$1.92

-65%NEW
Thumbnail 1Thumbnail 2

Hop Mothra IPA by Jim Nielsen | 5 Gallon Beer Recipe Kit | Extract

$53.99

$18.90

-65%NEW
Thumbnail 1

Economy Sulfur Burner

$51.99

$18.20

NEW
Thumbnail 1Thumbnail 2

Inert Gas System for Variable Volume Tanks

$344.99

NEW
Thumbnail 1

Indicator Solution for Aeration-Oxidation Free SO2 Test - 1 oz

$11.99

-65%NEW
Thumbnail 1Thumbnail 2

Vienna Lager by John Palmer | 5 Gallon Beer Recipe Kit | All-Grain

$33.99

$11.90

NEW
Thumbnail 1

Replacement Screen for 8 Cup French Press

$8.99

-65%NEW
Thumbnail 1

Replacement Screen for 12 Cup French Press

$13.99

$4.90

-65%NEW
Thumbnail 1Thumbnail 2

Vienna Lager by John Palmer | 5 Gallon Beer Recipe Kit | Extract

$39.99

$14.00

-65%NEW
Thumbnail 1

Replacement Screen for 3 Cup French Press

$8.99

$3.15

-65%NEW
Thumbnail 1

Replacement Gauge for WE398 Air Pump for Marchisio Variable Volume Tanks

$19.99

$7.00